Modelo: DXE-DM18
marca: Dexie, o serviço OEM está disponível
Lugar De Origem: China
Accuracy: 1%
Sensor atual DXE-DM18
TIPO
DXE-DM18-200A
DXE-DM18-300A
DXE-DM18-400A
DXE-DM18-500A
DXE-DM18-600A
DXE-DM18-700A
DXE-DM18-800A
DXE-DM18-900A
DXE-DM18-1000A
DXE-DM18-1100A
DXE-DM18-1200A
Características
● Excelente precisão- Erro de precisão <1%
● Linearidade muito boa- Erro de linearidade <0,5%
● Vários modelos- 200a, 300a, 400a, 500a, 600a, 700a, 800a, 900a, 1000a, 1100a, 1200
● largura de banda de ampla frequência- > 120KHz
● Alta força de compressão- > 2KV
● Faixa de temperatura de operação do sensor- -40 ℃ a +125 ℃
Aplicação Domai n
● Sistema de gerenciamento de bateria de veículos elétricos (BMS)
● Caixa de distribuição do sistema de bateria de veículos elétricos (BDU)
● Caixa de distribuição de alta tensão (PDU) para veículos elétricos
● Gerenciamento de energia de baterias industriais de lítio
Dados elétricos ( tensão de alimentação = VCC = 5V )
Parâmetros limitados (Nota: não exceda o valor máximo para evitar danos. Operação prolongada no valor máximo pode afetar a confiabilidade do dispositivo)
Parameter |
Symbol |
Specifications |
Unit |
Condition |
Minimum operating voltage |
Vcc |
4.8 |
V |
|
Maximum working voltage |
Vcc |
6 |
V |
|
Output voltage |
Vout |
5 |
V |
|
Storage temperature |
Ts |
-45-135 |
℃ |
|
Junction temperature |
Tj |
165 |
℃ |
|
ESD |
HBM |
8000 |
V |
HBM model per Mil-Std-883, Method 3015 |
ESD |
MM |
400 |
V |
MM model per JEDEC EIA/JESD22-A115 |
Latch-up test per JEDEC 78 |
|
200 |
mA |
|
Dissipation power |
Pd |
550 |
mW |
|
Dielectric Strength |
VD |
2000 |
V |
50Hz,1min |
Parâmetros padrão (a menos que especificado de outra forma: ta = 25 ℃ , cp = 0,1UF, vcc = 5v)
Parameter |
Symbol |
Specifications |
Unit |
Condition |
||
Minimum |
Standard |
Maximum |
||||
Supply Voltage |
Vcc |
4.8 |
5 |
5.2 |
V |
|
Working current @Ip=0A |
Ic |
|
10 |
15 |
Ma |
|
Static output voltage |
Vout |
2.48 |
2.5 |
2.52 |
V |
|
Output High Voltage |
VOH |
4.8 |
- |
- |
V |
|
Output Low Voltage |
VOL |
- |
- |
0.2 |
V |
|
Output resistance |
ROUT |
- |
- |
100 |
Ω |
|
Power on response time |
TPO |
- |
0.1 |
0.2 |
ms |
|
Output response time |
tRESPONSE |
- |
3.7 |
- |
us |
|
Bandwidth |
BW |
0 |
- |
120 |
KHz |
|
Ambient Temperature |
TA |
-40 |
- |
125 |
℃ |
|
Parâmetros de precisão (a menos que especificado de outra forma: ta = 25 ℃ , cp = 0,1UF, vcc = 5V)
Características de segurança
Parameter |
Symbol |
Specifications |
Unit |
Condition |
||
Minimum |
Standard |
Maximum |
||||
Sensitivity |
Sense |
9.90 |
10.00 |
10.10 |
mV/A |
DXE-DM18-200A |
6.60 |
6.67 |
6.73 |
mV/A |
DXE-DM18-300A |
||
4.95 |
5.00 |
5.05 |
mV/A |
DXE-DM18-400A |
||
3.96 |
4.00 |
4.04 |
mV/A |
DXE-DM18-500A |
||
3.30 |
3.33 |
3.37 |
mV/A |
DXE-DM18-600A |
||
2.83 |
2.86 |
2.89 |
mV/A |
DXE-DM18-700A |
||
2.48 |
2.50 |
2.53 |
mV/A |
DXE-DM18-800A |
||
2.20 |
2.22 |
2.24 |
mV/A |
DXE-DM18-900A |
||
1.98 |
2.00 |
2.02 |
mV/A |
DXE-DM18-1000A |
||
1.80 |
1.82 |
1.84 |
mV/A |
DXE-DM18-1100A |
||
1.65 |
1.67 |
1.68 |
mV/A |
DXE-DM18-1200A |
||
Linearity |
Lin |
-0.50 |
- |
0.50 |
% |
|
Temperature characteristics |
VOUT (T) |
-1.50 |
- |
1.50 |
% |
|
Sense(T) |
2.50 |
- |
2.50 |
% |
|
|
Measuring current |
IP |
-200.00 |
- |
200.00 |
A |
DXE-DM18-200A |
-300.00 |
- |
300.00 |
A |
DXE-DM18-300A |
||
-400.00 |
- |
400.00 |
A |
DXE-DM18-400A |
||
-500.00 |
- |
500.00 |
A |
DXE-DM18-500A |
||
-600.00 |
- |
600.00 |
A |
DXE-DM18-600A |
||
-700.00 |
- |
700.00 |
A |
DXE-DM18-700A |
||
-800.00 |
- |
800.00 |
A |
DXE-DM18-800A |
||
-900.00 |
- |
900.00 |
A |
DXE-DM18-900A |
||
-1000.00 |
- |
1000.00 |
A |
DXE-DM18-1000A |
||
-1100.00 |
- |
1100.00 |
A |
DXE-DM18-1100A |
||
-1200.00 |
- |
1200.00 |
A |
DXE-DM18-1200A |
||
Measuring range |
IP |
-220.00 |
- |
220.00 |
A |
DXE-DM18-200A |
-330.00 |
- |
330.00 |
A |
DXE-DM18-300A |
||
-440.00 |
- |
440.00 |
A |
DXE-DM18-400A |
||
-550.00 |
- |
550.00 |
A |
DXE-DM18-500A |
||
-660.00 |
- |
660.00 |
A |
DXE-DM18-600A |
||
-770.00 |
- |
770.00 |
A |
DXE-DM18-700A |
||
-880.00 |
- |
880.00 |
A |
DXE-DM18-800A |
||
-990.00 |
- |
990.00 |
A |
DXE-DM18-900A |
||
-1100.00 |
- |
1100.00 |
A |
DXE-DM18-1000A |
||
-1210.00 |
- |
1210.00 |
A |
DXE-DM18-1100A |
||
-1320.00 |
- |
1320.00 |
A |
DXE-DM18-1200A |
||
Output noise |
VP-P |
- |
20.00 |
- |
mV |
Cp=100nF,CL=1.5nF |
VRMS |
- |
2.30 |
- |
mV |
CP=100nF,CL=1.5nF |
Princípio de trabalho
Na corrente (IP = 0a), a tensão do pino de saída é metade da tensão da fonte de alimentação. Quando a corrente passa através do orifício através do meio do sensor a partir da direção para a frente, a tensão de saída aumenta correspondentemente. Pelo contrário, quando a corrente passa pelo orifício do meio do sensor na direção oposta, a tensão de saída diminui correspondentemente e a amplitude do aumento ou diminuição é simétrica.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.